MTL1000 RANGE
- Application: In conjunction with the DIN-rail.
- Embedded power-bus reduces power wiring up to 90%
- High packing density with 6.2mm wide slimline modules
- Trip amplifiers with 2 user set high/low alarm relays
- Status indication and alarm relay for quick maintenance
- Improved signal quality enhances plant performance
GALVANIC ISOLATOR - MTL5500 (Din Rail Type)
- Application: In conjunction with system (PLC, DCS, SIS, FGS, ETC) on I/Os to fulfill intrinsic safe (IS) protection method before going to field. Can be used with HART (Selected model only)
- Size Up Info: Application-
- Type of I/Os - AI, AO, DI, DO, vibration, pulse, RTD/Thermocouple , etc & quantity. Safety/Entity parameters of the field devices for safety parameter calculation if required.
GALVANIC ISOLATOR - MTL4500 (Backplane Type)
- Application: In conjunction with system (PLC, DCS, SIS, FGS, ETC) on I/Os to fulfill intrinsic safe (IS) protection method before going to field.
- Size Up Info: Application-
- Type of I/Os - AI, AO, DI, DO, etc & quantity Isolators are used with standard or custom backplanes. It can be used with any system (Yokogawa, Honeywell, Emerson, Invensys, ABB, ICS Triplex, etc). Safety/Entity parameters of the field devices for safety parameter calculation if required.
ZENER BARRIER - MTL7700 SERIES (Din Rail Type)
- Application: In conjunction with system (PLC, DCS, SIS, FGS, ETC) on I/Os to fulfill instrinsic safe (IS) protection method before going to field.
- Size Up Info: Application - Type of I/Os - AI, AO, DI, DO, etc
- Safety/Entity parameters of the field devices for safety parameter calculation if required.
ZENER BARRIER - MTL700 SERIES (Clamp Type System)
- Application: In conjunction with system (PLC, DCS, SIS, FGS, ETC) on I/Os to fulfill instrinsic safe (IS) protection method before going to field.
- Size Up Info: Application - Type of I/Os - AI, AO, DI, DO, etc
- Safety/Entity parameters of the field devices for safety parameter calculation if required.
SIGNAL SPD
- Application: Since power surge is protecting the income power, will need to protect control panel from surge coming from the field. Zone 2 with ATEX certification available
- Size Up Info: Protection for signal criteria: Loop type, Ampere, Data type
FOUNDATION FIELDBUS SPD
- Application: Foundation fieldbus transmitter, Control valve, Trunk & spur SPD, etc
- Size Up Info: Connected location eg. FF power supply (control room), field junction box or at field device
SPD FOR POWER SUPPLY
- Application: Incoming 3 phase power, Single phase power, 24VDC power. Series and parallel connection available
- Size Up Info: 3 phase or 1 phase, Volt, Current ratings, Protection rating
TELECOMMUNICATION SPD
- Application: Telco line
- Size Up Info: Type of Telco line (ADSL, Least line, etc), connector type
LOAD BRIDGE, CCTV, DOOR ACCESS, PABX, ANTENNA SPD
- Application: Load bridge, RF, special interface signal, antenna etc
- Size Up Info: Voltage level, connector type, frequency, signal type
HET FF POWER SUPPLY AND SIGNAL CONDITIONAL
- Application: FF power supply and signal conditioner for 'High Energy Trunk'. Couple with FF megablock. Good up to zone 2 application. Simplex or redundant type. New N+1 power supply. Mixing and matching with other manufacturer could be done.
- Size Up Info: Exi method, SPD and diagnostic module requirement, Use up to zone 2
- Simplex/redundant
FOUNDATION FIELDBUS BARRIER
- Application: Modular module of 6 and 12 spurs and lego type modular configuration. Also come with redundant fieldbus type. Come with manual and certification for fast delivery. Since it is modular in design, we can add-on module (SPD module, barrier module, terminator module, etc) easily. We can repair by replacing the module even in hazardous area (hot pluggable-patented technology). The total size and weight of the FF junction box is reduced by more than 50% over conventional type.
- Size Up Info:
- No. of spurs
- Use up to zone 1
- Simplex/redundant
- Exi method
- SPD and terminator requirement
- Accessories-Junction box (GRP or Stainless Steel), cable glands (Nickel plated brass or Stainless Steel)
FF DISPLAY/INDICATOR
- Application: Listen to the FF transmission and display up to 8 fields at 1 time
- Size Up Info: Panel/Field Mounted, SPD requirement
TEST EQUIPMENT & POWER HUB
- Application: Multiple devices is available to test the FF and Profibus (Selected model) network. We have to tester that you can take into zone 1 and info can be share later to the web for diagnostic purposes. We have also FF signal injector. As for full scale tester, we have portable units with battery pack and signal emulator.
- Size Up Info: Application required